Still deciding? Get samples of $ !
Request Sample
|
| Customization: | Available |
|---|---|
| Application: | 3D Printer |
| Speed: | Low Speed |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
| Parameter | Min | Typical | Max | Unit |
| Input Voltage(DC) | 20 | - | 50 | VDC |
| Output current | 0 | - | 5.6 | A |
| Pulse Signal Frequency | 0 | - | 200 | KHZ |
| Input Signal Current | 7 | 10 | 16 | mA |
| Peak | SW1 | SW2 | SW3 |
| 1.4A | on | on | on |
| 2.1A | off | on | on |
| 2.7A | on | off | on |
| 3.2A | off | off | on |
| 3.8A | on | on | off |
| 4.3A | off | on | off |
| 4.9A | on | off | off |
| 5.6A | off | off | off |
| Step/Rev | SW5 | SW6 | SW7 | SW8 |
| 400 | off | on | on | on |
| 800 | on | off | on | on |
| 1600 | off | off | on | on |
| 3200 | on | on | off | on |
| 6400 | off | on | off | on |
| 12800 | on | off | off | on |
| 25600 | off | off | off | on |
| 1000 | on | on | on | off |
| 2000 | off | on | on | off |
| 4000 | on | off | on | off |
| 5000 | off | off | on | off |
| 8000 | on | on | off | off |
| 10000 | off | on | off | off |
| 20000 | on | off | off | off |
| 40000 | off | off | off | off |
| Control Signal connector | |
| Name | Description |
| PUL+ | Pulse signal positive |
| PUL- | Pulse signal negative |
| DIR+ | Direction signal positive |
| DIR- | Direction signal negative |
| ENA+ | Enable signal positive, usually left unconnected(enable) |
| ENA- | Enable signal negative, usually left unconnected(enable) |
| GND | Power Ground |
| +VDC | Power supply, +20~+50 VDC |
| A+ | Motor phase A |
| A- | |
| B+ | Motor phase B |
| B- |