DM542 step drive digital 18V~60VDC Nema17/23 stepper motor controller
Overview:
The connection between the driver and the two-phase hybrid stepping motor is four-wire. The motor windings are connected in parallel and in
series, and the connection method is good. The high-speed performance is good, but the driver current is large (1.73 times the motor winding
current). The drive current is equal to the motor winding current.
Features | |
Input voltage | 18~60V DC |
Output current | 1.0A~4.2A(Peak) |
Input current | <4A |
Humidity | Not condensation, no water droplets |
Consumption | Consumption:80W |
Using environment | -10 ~ 45 ºC, avoid dust and corrosive gas |
Storage environment | -40~+70ºC |
Weight | 200g |
Control Signal | ||
Symbol | Name | |
PUL+ | Pulse signal + |
Compatible with 5/12/24V |
PUL- | Pulse signal - | |
DIR+ | Direction signal+ |
Compatible with 5/12/24V |
DIR- | Direction signal- | |
ENA+ | Enable signal + | / |
ENA- | Enable signal - | / |
Adjustment of troubleshooting | ||
Alarm indicator | Reasons | Measures |
LED off turn | Wrong connection for power | Check wiring of power |
LED off turn | Low-voltages for power | Enlarge voltage of power |
Motor doesn't run, without | Wrong connection of stepper motor | Correct its wiring |
holding torque | RESET signal is effective when offline | Make RESET ineffective |
Motor doesn't run, but maintains | Without input pulse signal | Adjust PMW & signal level |
holding torque | Without input pulse signal | Adjust PMW & signal level |
Motor runs wrong direction | Wrong wires' connection | Change connection for any of 2 wires |
Motor runs wrong direction | Wrong input direction signal | Change direction setting |
Motor's holding torque is | Too small relative to current setting | Correct rated current setting |
Motor's holding torque is | Acceleration is too fast | Reduce the acceleration |
Motor torque is too small | Motor stalls | Rule out mechanical failure |
Motor torque is too small | Driver does not match with the motor | Change a suitable driver |